OF-500 OptiFiber® Certifying OTDR Users Manual PN 1779484 September 2002, Rev. 4 6/06 © 2002-2006 Fluke Corporation. All rights reserved. Pr
OF-500 OptiFiber Certifying OTDR Users Manual Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176FAX 781.665.0780 - TestEquip
OF-500 OptiFiber Certifying OTDR Users Manual 90 Replacing the Battery Replace the lithium ion battery pack when its life becomes noticeably shorter.
Calibration 91 Calibration The tester requires a traceable calibration once a year to ensure that it meets or exceeds the published accuracy s
OF-500 OptiFiber Certifying OTDR Users Manual 92 Table 2. Troubleshooting the Tester Symptom 1: The keypad does not respond. Press and hold I until th
If Something Seems Wrong 93 Table 2. Troubleshooting the Tester (cont.) Symptom 6: The noise level on the OTDR trace has increased or the OTDR
OF-500 OptiFiber Certifying OTDR Users Manual 94 Signs of a Bad OTDR Connector Figure 37 shows traces from OTDRs with good and poor OTDR port connecti
Options and Accessories 95 Options and Accessories To order options and accessories (Tables 3 and 4), contact Fluke Networks. For the latest l
OF-500 OptiFiber Certifying OTDR Users Manual 96 Table 4. Accessories Accessory Fluke Networks Model Number FiberInspector Video Probe, 250X and 400
Options and Accessories 97 Table 4. Accessories (cont.) Accessory Fluke Networks Model Number Launch fiber, multimode, 62.5 µm, SC/ST, 100 m
OF-500 OptiFiber Certifying OTDR Users Manual 98 Table 4. Accessories (cont.) Accessory Fluke Networks Model Number SC connector adapters for OFTM-57
Options and Accessories 99 Table 4. Accessories (cont.) Accessory Fluke Networks Model Number SC/ST to ST/ST duplex 50 µm/125 µm reference te
1 OF-500 OptiFiber Certifying OTDR Note While this manual describes specific operating procedures for the OptiFiber tester, the fiber test methods des
OF-500 OptiFiber Certifying OTDR Users Manual 100 Table 4. Accessories (cont.) Accessory Fluke Networks Model Number AC adapter with line cord (speci
Options and Accessories 101 Table 4. Accessories (cont.) Accessory Fluke Networks Model Number SimpliFiber 1310 Source (SC) 8251-11 SimpliF
OF-500 OptiFiber Certifying OTDR Users Manual 102 Specifications Specifications apply at 23 oC (73 oF), unless otherwise noted. Environmental and Regu
Specifications 103 OTDR Specifications for OFTM-561xB Multimode Modules Testing speed < 10 s for two wavelengths at 2 km with 25 cm resolu
OF-500 OptiFiber Certifying OTDR Users Manual 104 OTDR Specifications for OFTM-561xB Multimode Modules (cont.) Event deadzones2 850 nm: 0.5 m typical
Specifications 105 OTDR Specifications for OFTM-561xB Multimode Modules (cont.) Loss threshold6 0.2 dB Distance accuracy7 ±1 m ±0.005 % of d
OF-500 OptiFiber Certifying OTDR Users Manual 106 OTDR Specifications for OFTM-573x Singlemode Modules Testing speed per wavelength Auto OTDR mode: 1
Specifications 107 OTDR Specifications for OFTM-573x Singlemode Modules (cont.) Event deadzones1 1310/1550 nm: 1 m typical Attenuation deadzo
OF-500 OptiFiber Certifying OTDR Users Manual 108 OTDR Specifications for OFTM-573x Singlemode Modules (cont.) Dynamic range6, 7 1310 nm: 26 dB typic
Specifications 109 OTDR Specifications for OFTM-573x Singlemode Modules (cont.) Reflectance accuracy9 ± 4 dB Optical return loss accuracy10
OF-500 OptiFiber Certifying OTDR Users Manual 2 • Optional modules add visual fault locator (OFTM-57xx only), power meter, and loss/length test set f
OF-500 OptiFiber Certifying OTDR Users Manual 110 Power Meter Specifications Testing speed, worst case 4.5 s (Far End Source mode) Input connector
Specifications 111 Power Meter Specifications (cont.) Power measurement uncertainty (accuracy) ± 0.25 dB1 Measurement linearity (18 °C to 28
OF-500 OptiFiber Certifying OTDR Users Manual 112 Loss/Length Specifications Specification OFTM-5x12B Multimode Modules OFTM-5732B Singlemode Modules
Specifications 113 Loss/Length Specifications (cont.) Specification OFTM-5612B Multimode Modules OFTM-5732 Singlemode Modules Maximum length
OF-500 OptiFiber Certifying OTDR Users Manual 114 Loss/Length Specifications (cont.) Specification OFTM-5612B Multimode Modules and OFTM-5732 Singlemo
Specifications 115 Loss/Length Specifications (cont.) Specification OFTM-5612B Multimode Modules OFTM-5732 Singlemode Modules Power measuremen
OF-500 OptiFiber Certifying OTDR Users Manual 116 Visual Fault Locator Specifications (OFTM-573x Modules) On/off control Controlled by the OptiFiber
Specifications 117 Power Battery type Lithium ion battery pack, 7.2 V Battery life 8 hr Auto OTDR operation with OFTM-5612 module, dual wavele
OF-500 OptiFiber Certifying OTDR Users Manual 118 Serial Interfaces The tester has a USB client interface and an EIA/TIA-232 (RS-232; DB9) interface f
Specifications 119 Table 6. 9-to-25-Pin Adapter 9-pin Connector 25-pin Connector 3 2 2 3 7 4 8 5 6 6 5 7 1 8 4 20 9 22 Shell Shell Keyboard
OF-500 OptiFiber Certifying OTDR Users Manual 120 FiberInspector Probe Specifications Magnification Switchable between 250X and 400X Camera type 0.
121 Index —A— ac adapter, 12 accessories optional, 95 standard, 4 Auto OTDR mode, 29 —B— battery backup battery, 90 charging, 12 replacement, 90 st
OF-500 OptiFiber Certifying OTDR Users Manual 122 test connections, 76 test setup, 73, 74 fiber ID options, 24 FiberInspector equipment, 47 image exa
Index (continued) 123 —P— parts, 95 power meter, 80 powering the tester, 12 Problem with Module, 92 problems (with the tester), 91 —R— receive fi
OF-500 OptiFiber Certifying OTDR Users Manual 4 Unpacking The OF-500 OptiFiber packages come with the accessories listed below. If something is damage
Unpacking 5 Model OF-500-03 • OF-500 OptiFiber tester with battery pack • OFTM-5730 singlemode OTDR module • 9/125 µm singlemode launch fi
OF-500 OptiFiber Certifying OTDR Users Manual 6 Model OF-500-13 • OF-500 OptiFiber tester with battery pack • OFTM-5732 singlemode OTDR module with
Unpacking 7 • OptiFiber Product Manuals CD • Smart Remote Users Manual • Smart Remote Product CD • LinkWare Software CD Model OF-500-35 •
OF-500 OptiFiber Certifying OTDR Users Manual 8 Model OF-500-45 • OF-500 OptiFiber tester with battery pack • OFTM-5612B multimode OTDR module with
Safety Information 9 Safety Information Table 1 shows the international electrical symbols used on the tester or in this manual. Table 1. Inte
LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke Networks product is warranted to be free from defects in material and workmanship under normal
OF-500 OptiFiber Certifying OTDR Users Manual 10 • If this equipment is used in a manner not specified by the manufacturer, the protection provided b
Safety Information 11 • Read the instructions for splice machines before using the OTDR to monitor splicing procedures. The OTDR can interfer
OF-500 OptiFiber Certifying OTDR Users Manual 12 Powering the Tester You can power the tester with the ac adapter included or with the removable lith
Powering the Tester 13 ajt20f.eps Figure 1. Battery Pack Features
OF-500 OptiFiber Certifying OTDR Users Manual 14 Changing the Language To change the tester’s language, do the following: 1 Press S. 2 Press N once
Verifying Operation 15 ajt56f.eps Figure 2. Removing the Module Verifying Operation The tester performs a basic self-test when you turn it on
OF-500 OptiFiber Certifying OTDR Users Manual 16 Basic Features The following sections describe the tester's basic features and introduce the tes
Basic Features 17 A LCD display with backlight and adjustable brightness. B s: Saves test results on the removable memory card or in internal
OF-500 OptiFiber Certifying OTDR Users Manual 18 Side and Top Panel Features Figure 4 describes the tester’s connectors and other features on the side
Basic Features 19 A Connector for the ac adapter. The LED turns on when the adapter is connected to ac power. B USB port for uploading test r
i Table of Contents Title Page Overview of Features...
OF-500 OptiFiber Certifying OTDR Users Manual 20 The HOME Screen The HOME screen shows important test and job settings you might need to change to con
Basic Features 21 A Model number of the installed module. B The current date and time. C Owner’s logo. See the OptiFiber Technical Referenc
OF-500 OptiFiber Certifying OTDR Users Manual 22 Using the Setup Menus To access the tester’s settings, press S. Figure 6 introduces the SETUP menus.
Basic Features 23 A The settings available on the current tab. Note To see details about a setting, highlight the setting; then press H. B U
OF-500 OptiFiber Certifying OTDR Users Manual 24 Using the Online Help When you press H, the tester shows a help topic that relates to the current scr
Checking the Tester’s Status 25 Checking the Tester’s Status The following steps help you verify that the tester is ready for use. Checking
OF-500 OptiFiber Certifying OTDR Users Manual 26 Preparing to Save Tests The following steps summarize how to configure settings that apply to saved t
Cleaning and Inspecting Fiber Connectors and Adapters 27 Cleaning and Inspecting Fiber Connectors and Adapters Always clean and inspect fiber
OF-500 OptiFiber Certifying OTDR Users Manual 28 Testing Your Reference Test Cords and Launch Fiber You should test your reference test cords and laun
Using the OTDR 29 OVERALL LOSS and FIBER LENGTH include the loss and length of the launch and receive fibers, unless you use the launch/receiv
OF-500 OptiFiber Certifying OTDR Users Manual ii Charging the Battery...
OF-500 OptiFiber Certifying OTDR Users Manual 30 OTDR Connection Quality When you run an OTDR test, the tester determines the quality of OTDR port con
Using the OTDR 31 Running the OTDR Test Figure 8 shows the equipment needed for using the OTDR. ajt42f.eps A Tester with OFTM-56xxB or OFT
OF-500 OptiFiber Certifying OTDR Users Manual 32 Using the OTDR 1 Select Auto OTDR mode: On the HOME screen, press A Change Test; then select Auto OT
Using the OTDR 33 ajt32f.eps Figure 9. Connecting the OTDR to Installed Fiber (no receive fiber)
OF-500 OptiFiber Certifying OTDR Users Manual 34 ajt01f.eps Figure 10. Connecting the OTDR to Installed Fiber (with receive fiber)
Using the OTDR 35 ajt33f.eps Figure 11. Connecting the OTDR to Spooled Cable
OF-500 OptiFiber Certifying OTDR Users Manual 36 KAHIJLCBEMFGDN ajt16f.eps Figure 12. OTDR Trace Screen
Using the OTDR 37 A Wavelength for the trace and the End setting on the Job tab in SETUP. If the test ran at two wavelengths, press A to switc
OF-500 OptiFiber Certifying OTDR Users Manual 38 Comparing OTDR Traces The trace overlay function lets you see two OTDR traces at the same time. This
Cleaning the OTDR Connector 39 Cleaning the OTDR Connector Note Typically, the OTDR connector requires cleaning only if it has been touched. U
Contents (continued) iii Cleaning the Loss/Length Connectors... 54 Cleaning
OF-500 OptiFiber Certifying OTDR Users Manual 40 Using the ChannelMap Function The ChannelMap function creates a map of the cabling under test. The m
Using the ChannelMap Function 41 ajt48f.eps A Tester with OTDR module B Memory card (optional) C Spare battery pack (optional) D AC adap
OF-500 OptiFiber Certifying OTDR Users Manual 42 Using the ChannelMap Function 1 Select ChannelMap mode: On the HOME screen, press A Change Test; the
Using the ChannelMap Function 43 ajt55f.eps Figure 15. ChannelMap Test Connections
OF-500 OptiFiber Certifying OTDR Users Manual 44 DBFCEA ajt25f.eps Figure 16. ChannelMap Diagram Features
Using the ChannelMap Function 45 A The length of the channel, including the launch fiber. Note The FIBER LENGTH shown is the actual length of
OF-500 OptiFiber Certifying OTDR Users Manual 46 Using the FiberInspector Option The OFTM-5352 FiberInspector Video Probe connects to an OptiFiber fi
Using the FiberInspector Option 47 ajt43f.eps A OptiFiber tester B Memory card (optional) C Spare battery pack (optional) D AC adapter w
OF-500 OptiFiber Certifying OTDR Users Manual 48 Using the FiberInspector Probe 1 On the System tab in Setup, set CAMERA TYPE to match the magnificat
Using the FiberInspector Option 49 ajt57f.eps Figure 18. Using the FiberInspector Probe
OF-500 OptiFiber Certifying OTDR Users Manual iv Options and Accessories...
OF-500 OptiFiber Certifying OTDR Users Manual 50 Dirt on coreClean, with light atfar endDirty patch panel connector(left uncovered)Wiped with fingerti
Using the Loss/Length Option 51 Using the Loss/Length Option The loss/length measurement option provides the following features, in addition
OF-500 OptiFiber Certifying OTDR Users Manual 52 Changing the Connector Adapter You can change the module's input connector adapter (Figure 20) t
Using the Loss/Length Option 53 ajt61f.eps Figure 21. Changing the Connector Adapter
OF-500 OptiFiber Certifying OTDR Users Manual 54 Cleaning the Loss/Length Connectors Always clean and inspect fiber connectors before making connectio
Using the Loss/Length Option 55 About Setting the Reference Setting a reference lets the tester automatically subtract out the losses due to
OF-500 OptiFiber Certifying OTDR Users Manual 56 Setting the Number of Adapters and Splices The NUMBER OF ADAPTERS and NUMBER OF SPLICES settings are
Using the Loss/Length Option 57 ajt22f.eps Figure 22. Example of How to Determine the NUMBER OF ADAPTERS Setting
OF-500 OptiFiber Certifying OTDR Users Manual 58 Using Mandrels for Testing Multimode Fiber You should use mandrels when testing multimode fiber. Mand
Using the Loss/Length Option 59 ajt02f.eps Figure 23. Wrapping a Reference test cord Around a Mandrel
v List of Figures Figure Title Page 1. Battery Pack Features...
OF-500 OptiFiber Certifying OTDR Users Manual 60 Testing in Smart Remote Mode Use Smart Remote mode to test and certify dual-fiber cabling. In this mo
Using the Loss/Length Option 61 Loss/Length Testing in Smart Remote Mode 1 Turn on all test equipment and let it warm up for 5 minutes. 2 On
OF-500 OptiFiber Certifying OTDR Users Manual 62 Loss/Length Testing in Smart Remote Mode (cont.) 6 Clean the tester's and source's OUTPUT
Using the Loss/Length Option 63 ajt05f.eps Figure 25. Smart Remote Mode Reference Connections
OF-500 OptiFiber Certifying OTDR Users Manual 64 Loss/Length Testing in Smart Remote Mode (cont.) 11 Clean the connectors on the cabling to be tested
Using the Loss/Length Option 65 ajt08f.eps Figure 26. Smart Remote Mode Test Connections
OF-500 OptiFiber Certifying OTDR Users Manual 66 Testing in Loopback Mode Use Loopback mode to test spools of cable, segments of uninstalled cable, pa
Using the Loss/Length Option 67 ajt45f.eps A Tester with OFTM-5612B or OFTM-5732 module. Match connector adapter to the connectors in the l
OF-500 OptiFiber Certifying OTDR Users Manual 68 Loss/Length Testing in Loopback Mode 1 Turn on the tester and let it warm up for 5 minutes. 2 On th
Using the Loss/Length Option 69 ajt06f.eps Figure 28. Loopback Mode Reference Connections
OF-500 OptiFiber Certifying OTDR Users Manual vi 18. Using the FiberInspector Probe...
OF-500 OptiFiber Certifying OTDR Users Manual 70 Loss/Length Testing in Loopback Mode (cont.) 7 Optional: From the TEST SETUP screen, you can enter
Using the Loss/Length Option 71 ajt09f.eps Figure 29. Loopback Mode Test Connections
OF-500 OptiFiber Certifying OTDR Users Manual 72 Testing in Far End Source Mode Use Far End Source mode to measure power or power loss at one waveleng
Using the Loss/Length Option 73 Loss Testing in Far End Source Mode 1 Turn on all test equipment and let it warm up for 5 minutes. 2 Verify
OF-500 OptiFiber Certifying OTDR Users Manual 74 Loss Testing in Far End Source Mode (cont.) 6 Clean the connectors on the source and the reference t
Using the Loss/Length Option 75 ajt07f.eps Figure 31. Far End Source Mode Reference Connections
OF-500 OptiFiber Certifying OTDR Users Manual 76 ajt10f.eps Figure 32. Far End Source Mode Test Connections
Using the Visual Fault Locator 77 Using the Visual Fault Locator The visual fault locator (VFL) is available with OFTM-573x modules. The VFL h
OF-500 OptiFiber Certifying OTDR Users Manual 78 Using the Visual Fault Locator 1 Clean the connectors on the patch cord, if used, and the fiber to b
Using the Visual Fault Locator 79 ajt03f.eps Figure34. Using the Visual Fault Locator
vii List of Tables Table Title Page 1. International Electrical Symbols...
OF-500 OptiFiber Certifying OTDR Users Manual 80 Using the Power Meter Option The power meter option lets you monitor the output power produced by a s
Using the Power Meter Option 81 ajt47f.eps A Tester with OFTM-5611B, OFTM-5612B, or OFTM-5731, or OFTM-5732 module. Match the connector ada
OF-500 OptiFiber Certifying OTDR Users Manual 82 Using the Power Meter 1 Select Power Meter mode: On the HOME screen, press A Change Test; then selec
Using the Power Meter Option 83 ajt11f.eps Figure 36. Connections for Monitoring Optical Power
OF-500 OptiFiber Certifying OTDR Users Manual 84 Overview of Memory Functions You can save test results on a removable memory card or in the tester’s
About LinkWare and LinkWare Stats Software 85 OptiFiber software version 2.0 supports cards up to 4 gigabytes. Later versions may support lar
OF-500 OptiFiber Certifying OTDR Users Manual 86 Maintenance WWarning To avoid possible fire, electric shock, personal injury, or damage to the tester
Maintenance 87 WCaution To avoid unexpected loss of power, connect the ac adapter to the tester when updating the software. Note Updating the
OF-500 OptiFiber Certifying OTDR Users Manual 88 5 Click Start to start the update process. 6 The OptiFiber tester reboots after the update is compl
Maintenance 89 9 Press F on OptiFiber; then select Install Software Update. The tester makes initial choices on which software to install bas
Komentarze do niniejszej Instrukcji